GENERAL SPECIFICATIONS
- Single-component, solvent-based, polyurethane resin once dry forms a continuous and highly adherent film on supports such as concrete, mortar or wood, increasing adhesion for liquid waterproofing systems.
- Its consumption depends on the condition of the support, any irregularities or level of planimetry. Always apply a thin layer, never a thick one.
- It must be applied in sound and resistant substrates, with no presence of humidity/water on the surface whether at the time of application or subsequently (pressure from phreatic water level, damp-water).
- In repairs and membrane overlaps its consumption is between 50-100 g/sqm
- Possibility of applying in combination with mineral fillers (siliceous aggregate) on very irregular substrates or to improve mechanical adhesion in the event of rain.
PACKAGING
Metallic pail: 5 kg and 20 kg.
STORAGE AND SHELF LIFE
12-months shelf life is stored in original containers in a dry environment at a temperature between 5-35 ºC (41-95°F). Keep away from direct sunlight, extreme heat, cold or moisture. Once the tin has been opened, the product must be used.
Concrete substrate: Concrete should be completely cured (concrete curing takes 28 days) or, in any case, the maximum level of humidity allowed for the substrate should be verified, depending on the primer used. Concrete must be strong, cohesive and dry, having a correct planimetry, high surface resistance, eliminating laitance, graise, oils or release agents, without excessive irregularities. Therefore, the previous action of sanding, polishing, milling or shot-blasting will be assessed by the applicator to achieve a preparation of the substrate according to ICRI Guide 03732, CSP values 3 to 5. Existing holes or areas with a lack of material must be repaired using some of our epoxy resins: Primer EP-1020/Primer EP-1010. Mastic PU must be used on fissures or small cracks on the surface. Joint filling for installation, work and consolidation of surfaces. General cleaning of the substrate, removing existing dust, dirt, grease or efflorescence. The substrates must be resistant and cohesive. Mix the two components using a mechanical shaker for approximately 4-5 minutes (medium speed). Apply the resin in two or more thin crossed coats until the desired planimetry is achieved. (always wait for drying before recoat). Consumption around 150 g/sqm depending on the roughness of the substrate. Apply as many coats as the substrate needs. Apply thin coat, never thick. Always respect the recoat time between coats or between different materials. In case of rain, apply a thin layer, consumption approx. 100-150g/sqm. In applications of repairs/overlaps/joining bridge between already cured membranes, this consumption could be less.
NOTE: For other types of substrates, weather conditions or the substrate to be applied, consult our technical department.
HEALTH AND SAFETY
Respiratory Protection: When handling or spraying use an air-purifying respirator. Skin protection: Use rubber gloves, remove immediately after contamination. Wear clean body-covering. Wash thoroughly with soap and water after work and before eating, drinking, or smoking. Eye / Face: Wear safety goggles to prevent splashing and exposure to particles in the air. Waste: Waste generation should be avoided or minimized. Incinerate under controlled conditions in accordance with local laws and national regulations. Re-occupancy of the work site without respiratory equipment is minimum 24 hours providing the correct ventilation for the area sprayed. Contractors and applicators must comply with all applicable and appropriate guidelines for storage and safety guidelines.These safety recommendations for handling, are necessary for the implementation process as well as in the pre and post, on exposure to the loading machinery. Dispose waste in accordance with star or/and local regulations.
TECHNICAL AND CHEMICAL PROPERTIES
PROPERTIES
|
RESULT
|
Density ISO 1675
|
1.12 ±0.08 g/cm³
|
Viscosity ISO 2555 |
70~300 cps |
Solids content ISO 1768
|
70~75%
|
VOC content |
270 g/l |
Adhesion to concrete
|
> 1.5 MPa
|
Times: dry/ recoat
|
2~3 hours / 3~48 hours
|
Application temperature range (substrate / environment)
|
5~35ºC / 5~30ºC (41~95ºF / 41~86ºF)
|
Maximum moisture (substrate/ environmental)
|
±4% / ±80%
|
Dilution (in case of electrical equipment application)
|
Desmosolvent (5-6%)
|
Results performed in the laboratory at 23ºC (73ºF) and 50% RH, under controllable conditions. These values may vary depending on the application, climatology, or substrate conditions.